| Datasheet | Download |
| INMETRO Installation Manual | Download |
| IECEx certificate | Download |
| ATEX certificate | Download |
| UL certificate of compliance | Download |
| UKCA Certificate | Download |
| INMETRO certificate | Download |
| Ex EAC TR CU 012/2011 Certificate | Download |
| CCOE PESO | Download |
| DNV Type Approval | Download |
| ECAS Ex Approval | Download |
| Ingress Protection certificate | Download |
| Ingress Protection certificate | Download |
| Declaration of Conformity | Download |
| Declaration of Conformity UKCA | Download |
| 2D drawing (PDF) | Download |
| 2D drawing (DWG) | Download |
| 3D drawing (STEP) | Download |
| Wiring Schematic DC voltage | Download |
| Wiring Schematic AC voltage | Download |
| Nameplate Drawing | Download |
| Equipment Tag Drawing | Download |
| Duty Label Drawing | Download |
| Pole Mount & Sun Shade Drawing | Download |
| Maximum output: | High power level: 123dB(A) @ 1 m +/- 3dB [114dB(A) @ 10ft/3m +/- 3dB] Default power level: 118dB(A) @ 1 m +/- 3dB [109dB(A) @ 10ft/3m +/- 3dB] |
| Nominal output: | High power level: 120dB(A) @ 1m +/- 3dB [111dB(A) @ 10ft/3m] +/- 3dB Default power level: 115dB(A) @ 1m +/- 3dB [106dB(A) @ 10ft/3m] +/- 3dB |
| No. of tones: | 64 (UKOOA / PFEER compliant) |
| No. of stages: | 4 |
| Volume control: | Full range |
| Effective range: | 200m/656ft @ 1KHz |
| Voltages DC: | 24Vdc (11.5-54Vdc) |
| Voltages AC: | 230Vac (100-240Vac) |
| In-rush: | 815mA within 4ms @ 24Vdc |
| Stage switching: | DC units: positive or negative AC units: common supply line |
| Safety Integrity Level: | Product version A: SIL1 and SIL2 Route 2H Product version S: SIL2 Route 1H with diagnostics SFF: >99% See install manual for reliability & functional safety data |
| Ingress protection: | EN60529: IP66/67 |
| Enclosure material: | 316L Stainless Steel |
| Enclosure colour: | Red |
| Enclosure finish: | Chromate & powder coated finish ISO 12944-6 CX, C5VH & C5H |
| Cable entries: | 3 x M20x1.5mm Stopping plugs included |
| Stopping plugs: | Stainless Steel |
| Terminals: | 0.5 – 2.5mm² (20-14 AWG) Pluggable & duplicated terminals |
| Line monitoring: | Diode polarized for use in supervised circuits Blocking diode for reverse polarity monitoring Blocking diode included EOL Min. 500 Ohm 2W, or 3k3 Ohm 0.5W resistor or diode (DC versions) can be fitted |
| Ground/Earth stud: | M5 |
| Enclosure volume: | <2 litres |
| Installation temp: | -50° to +70°C (-58°F to +158°F) |
| Storage temp: | -50° to +70°C (-58°F to +158°F) |
| Relative humidity: | 99% |
| MTBF DC: | 93.92 years / 822,706 hours – MIL 217 |
| MTBF AC: | 46.66 years / 408,508 hours – MIL 217 |
| Weight: | 6.25kg/13.75lbs |
| Part Code: | Identifier: | Description: | |
|---|---|---|---|
| Product type: | STExS2 | STExS2 alarm horn sounder | |
| Horn type: | F | Flare re-entrant horn | |
| Voltage: | DC024 AC230 | 11.5-54Vdc 100-240Vac | |
| Cable entries:[e] | A B C D E F G | 3 x M20x1.5mm 2 × 1/2" NPT – adaptors 2 × 3/4" NPT – adaptors 2 x M25x1.5mm – adaptors 1 × 1/2" NPT – adaptor 1 × 3/4" NPT – adaptor 1 x M25x1.5mm – adaptor | |
| Stopping plug/adaptor material: [m] | S | Stainless steel | |
| Bracket material: [s] | 1 3 | A4 316 Stainless Steel A4 316 St/St with Equip. Tag | |
| Product version: [v] | A S T | UL, cUL, ULC, IECEx, ATEX, DNV, Ex EAC INMETRO, SIL1 & SIL2 Route 2H UL, cUL, ULC, IECEx, ATEX, Ex EAC, INMETRO SIL2 Route 1H with diagnostics SFF: >99% IECEx, ATEX, Ex EAC, INMETRO Telephone/Relay initiate | |
| Product option: [o] | 1 Z X Y K V | Standard product Custom alarm tone software – contact E2S Custom configuration – contact E2S Stage control Config. 4 Stage control Config. 5 (DC) and Config. 2 (AC) Stage control Config. 6 | |
| Enclosure colour: [x] | R S | Red Special – contact E2S for alternative enclosure colours | |
| Accessories | |||
| SP65-0001-A4 | |||
| SP65-0003-A4 | |||
| Please review the installation manual and wiring schematics for remote stage control and EOL resistor monitoring configuration options: | |||
| Config. 1 [DC]: | Factory default. Common negative, positive switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only | ||
| Config. 2 [DC]: | User setting. Common positive, negative switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only | ||
| Config. 3 [DC]: | User setting. Common negative, positive switching activation of Alarm Stages 1 & 2 with EOL on both stages. Reverse polarity monitoring | ||
| Config. 4 [DC]: | Product option ‘Y’. Independent activation of Alarm Stages 1 & 2 with EOL on both stages. Forward polarity monitoring | ||
| Config. 5 [DC]: | Product option ‘K’. Horn continuously powered. Voltage free activation of up to 3 alarm stages | ||
| Config. 6 [DC]: | Product option ‘V’. Independent activation of up to 4 Alarm Stages with EOL on all stages. Forward polarity monitoring | ||
| Config. 1 [AC]: | Factory default. Up to 4 Alarm Stages. Stage 1 activated at power on. Stages 2, 3 and 4 via volt free contacts | ||
| Config. 2 [AC]: | Product option ‘K’. Horn continuously powered. Voltage free activation of up to 3 alarm stages | ||
| NominalVoltage: | Voltagerange: | Default Powercurrent: | Default Power Max.current: | High powercurrent: | High Power Max.current: | In-rush: |
|---|---|---|---|---|---|---|
| 12Vdc | 11.5-54Vdc | 289mA | 324mA | 356mA | 740mA | - |
| 24Vdc | 11.5-54Vdc | 324mA | 324mA | 740mA | 740mA | 815mA <4ms |
| 48Vdc | 11.5-54Vdc | 195mA | 324mA | 391mA | 740mA | - |
| 115Vac 50/60Hz | 100-240V ac | 125mA | 138mA | 282mA | 325mA | - |
| 230Vac 50/60Hz | 100-240V ac | 78mA | 138mA | 167mA | 325mA | - |
| Stage 1 | WAV file | Frequency Description. | Stage 2 | Stage 3 |
|---|---|---|---|---|
| T 1 | 1000 Continuous – PFEER Toxic Gas | Any | T 2 | |
| T 2 | 1200/500 @ 1Hz Sweeping – DIN / PFEER P.T.A.P. | Any | T 3 | |
| T 3 | 1000 @ 0.5Hz (1s on, 1s off) Intermittent – PFEER Gen. Alarm | Any | T 2 | |
| T 4 | 1.4KH-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s – NF C 48-265 | Any | T 24 | |
| T 5 | 544(100mS)/440 (400mS) – NF S 32-001 | Any | T 19 | |
| T 6 | 1500/500 – (0.5s on , 0.5s off) x3 + 1s gap – AS4428 | Any | T 44 | |
| T 7 | 500-1500Hz Sweeping 2 sec on 1 sec off – AS4428 | Any | T 44 | |
| T 8 | 500/1200Hz @ 0.26Hz(3.3s on, 0.5s off) – NEN 2575 | Any | T 24 | |
| T 9 | 1000 (1s on, 1s off)x7 + (7s on, 1s off) – IMO Code 1a | Any | T 34 | |
| T 10 | 1000 (1s on, 1s off)x7 + (7s on, 1s off) – IMO Code 1a | Any | T 34 | |
| T 11 | 420(0.5s on, 0.5s off)x3 + 1s gap – ISO 8201 Temporal | Any | T 1 | |
| T 12 | 1000(0.5s on, 0.5s off)x3 + 1s gap – ISO 8201 Temporal | Any | T 1 | |
| T 13 | 422/775 – (0.85 on, 0.5 off) x3 + 1s gap – NFPA Temporal | Any | T 1 | |
| T 14 | 1000/2000 @ 1Hz – Singapore | Any | T 3 | |
| T 15 | 300 Continuous | Any | T 24 | |
| T 16 | 440 Continuous | Any | T 24 | |
| T 17 | 470 Continuous | Any | T 24 | |
| T 18 | 500 Continuous – IMO code 2 (Low) | Any | T 24 | |
| T 19 | 554 Continuous | Any | T 24 | |
| T 20 | 660 Continuous | Any | T 24 | |
| T 21 | 800 Continuous – IMO code 2 (High) | Any | T 24 | |
| T 22 | 1200 Continuous | Any | T 24 | |
| T 23 | 2000 Continuous | Any | T 3 | |
| T 24 | 2400 Continuous | Any | T 20 | |
| T 25 | 440 @ 0.83Hz (0.60s on, 0.60s off) Intermittent | Any | T 44 | |
| T 26 | 470 @ 0.9Hz (0.55s on, 0.55s off) Intermittent | Any | T 44 | |
| T 27 | 470 @ 5Hz (0.10s on, 0.10s off) Intermittent | Any | T 44 | |
| T 28 | 544 @ 1.14Hz (0.43s on, 0.44s off) Intermittent | Any | T 24 | |
| T 29 | 655 @ 0.875Hz (0.57s on, 0.57s off) Intermittent | Any | T 44 | |
| T 30 | 660 @ 0.28Hz (1.80s on, 1.80s off) Intermittent | Any | T 24 | |
| T 31 | 660 @ 3.3Hz (0.15s on, 0.15s off) Intermittent | Any | T 24 | |
| T 32 | 745 @ 1Hz (0.50s on, 0.50s off) Intermittent | Any | T 24 | |
| T 33 | 800 (0.25s on, 1.00s off) Intermittent | Any | T 24 | |
| T 34 | 800 @ 2Hz (0.25s on, 0.25s off) – IMO code 3.a (High) | Any | T 24 | |
| T 35 | 1000 @ 1Hz (0.50s on, 0.50s off) Intermittent | Any | T 24 | |
| T 36 | 2400 @ 1Hz (0.50s on, 0.50s off) Intermittent | Any | T 24 | |
| T 37 | 2900 @ 5Hz (0.10s on, 0.10s off) Intermittent | Any | T 24 | |
| T 38 | 363/518 @ 1Hz (0.50s / 0.50s) Alternating | Any | T 8 | |
| T 39 | 450/500 @ 2Hz (0.25s / 0.25s) Alternating | Any | T 8 | |
| T 40 | 554/440 @ 1Hz (0.50s / 0.50s) Alternating | Any | T 24 | |
| T 41 | 554/440 @ 0.65Hz (0.76s / 0.76s) Alternating | Any | T 8 | |
| T 42 | 561/760 @ 0.83Hz (0.60s / 0.60s) Alternating | Any | T 8 | |
| T 43 | 780/600 @ 0.96Hz (0.52s / 0.52s) Alternating | Any | T 8 | |
| T 44 | 800/1000 @ 2Hz (0.25s / 0.25s) Alternating | Any | T 24 | |
| T 45 | 970/800 @ 2Hz (0.25s / 0.25s) Alternating | Any | T 8 | |
| T 46 | 800/1000 @ 0.875Hz (0.57s / 0.57s) Alternating | Any | T 24 | |
| T 47 | 2400/2900 @ 2Hz (0.25s / 0.25s) Alternating | Any | T 24 | |
| T 48 | 500/1200 @ 0.3Hz (1.67s / 1.67s) Sweeping | Any | T 24 | |
| T 49 | 560/1055 @ 0.18Hz (2.73s / 2.73s) Sweeping | Any | T 24 | |
| T 50 | 560/1055 @ 3.3Hz (0.15s / 0.15s) Sweeping | Any | T 24 | |
| T 51 | 600/1250 @ 0.125Hz (4s / 4s) Sweeping | Any | T 24 | |
| T 52 | 660/1200 @ 1Hz (0.50s / 0.50s) Sweeping | Any | T 24 | |
| T 53 | 800/1000 @ 1Hz (0.50s / 0.50s) Sweeping | Any | T 24 | |
| T 54 | 800/1000 @ 7Hz (0.07s / 0.07s) Sweeping | Any | T 24 | |
| T 55 | 800/1000 @ 50Hz (0.01s / 0.01s) Sweeping | Any | T 24 | |
| T 56 | 2400/2900 @ 7Hz (0.07s / 0.07s) Sweeping | Any | T 24 | |
| T 57 | 2400/2900 @ 1Hz (0.50s / 0.50s) Sweeping | Any | T 24 | |
| T 58 | 2400/2900 @ 50Hz (0.01s / 0.01s) Sweeping | Any | T 24 | |
| T 59 | 2500/3000 @ 2Hz (0.25s / 0.25s) Sweeping | Any | T 24 | |
| T 60 | 2500/3000 @ 7.7Hz (0.65s / 0.65s) Sweeping | Any | T 24 | |
| T 61 | 800Hz Motor Siren | Any | T 24 | |
| T 62 | 1200Hz Motor Siren | Any | T 24 | |
| T 63 | 2400Hz Motor Siren | Any | T 24 | |
| T 64 | Simulated Bell | Any | T 21 |