D1xC2X05F 123dB(A) Alarm Horn & 5J Strobe Horn 123dB(A) and 5J Xenon

Features and Functions

  • Maximum sound pressure level output of 123dB(A)
  • Automatic synchronisation on multi-beacon & sounder systems
  • UL464 / CAN/ULC-S525 & UL1638 / CAN/ULC-S526
Inmetro
Ul badge certified
Ul
Ulc
Iecex approval
Atex approval
Csfm
Peso
Ce approval
Ukca

Overview

Featuring 64 alarm tones, each of the 4 stage/channels can be remotely activated. Class D amplification provides a high sound output with a choice of two power modes. The threaded flameproof joint, multiple cable entries and duplicated, pluggable termination simplifies both installation and routine maintenance. The 24Vdc Class I version is approved for public (alarm horn) and private mode fire alarm use. SIL1 & SIL2 compliant to IEC61508 (2010) as standard.
Downloads
Datasheet Download
INMETRO Installation Manual Download
IECEx certificate Download
ATEX certificate Download
CSFM Listing Download
UL certificate of compliance Download
UKCA Certificate Download
INMETRO certificate Download
CCOE PESO Download
ECAS Ex Approval Download
Ingress Protection certificate Download
Declaration of Conformity Download
Declaration of Conformity UKCA Download
2D drawing (PDF) Download
2D drawing (DWG) Download
3D drawing (STEP) Download
Wiring Schematic DC voltage Download
Wiring Schematic AC voltage Download
Nameplate Drawing Download
Equipment Tag Drawing Download
Duty Label Drawing Download
Pole Mount & Sun Shade Drawing Download
Specification
Maximum output: High power level: 123dB(A) @ 1 m +/- 3dB
[114dB(A) @ 10ft/3m +/- 3dB]
Default power level: 120dB(A) @ 1 m +/- 3dB
[111dB(A) @ 10ft/3m +/- 3dB]
Nominal output: High power level: 118dB(A) @ 1m +/- 3dB
[109dB(A) @ 10ft/3m] +/- 3dB
Default power level: 115dB(A) @ 1m +/- 3dB
[106dB(A) @ 10ft/3m +/- 3dB]
No. of tones: 64 (UKOOA / PFEER compliant)
No. of stages: 4
Volume control: Full range
Effective range: 200m/656ft @ 1KHz
Voltages DC: 24Vdc (20-28Vdc)
Voltages AC: 110-120Vac, 220-240Vac
Stage switching: DC units: negative or positive
AC units: common supply line
Energy: 5 Joules (5Ws)
Flash rates: Option 1: 1Hz (60 fpm)
Option 2: 1.5Hz (90 fpm)
Option 3: Double Strike
Eff. Intensity: 143 cd* – measured ref. to I.E.S.
250 cd – calculated from energy (J)
Peak Candela: 46,976 cd* – measured ref. to I.E.S.
500,000 cd – calculated from energy (J)
Lens colours: Amber, Blue, Clear, Green, Magenta, Red & Yellow
Tube life : Emissions reduced to 70% > 5 million flashes
Safety Integrity Level: SIL1 and SIL2 Route 2H IEC61508 (2010)
Ingress protection: EN60529: IP66/67
UL50E / NEMA250: 4 / 4X / 3R / 13
Enclosure material: Marine grade aluminium LM6 – copper free
Enclosure finish: Chromate & powder coated finish
ISO 12944-6 CX, C5VH & C5H
Enclosure colour: Red or Grey, custom colours available on request
Cable entries: 1×1/2"NPT & 2xM20 – thread adaptors available
Terminals: 0.5 – 2.5mm² (20-14 AWG) Pluggable, duplicated terminals
Grounding stud: M5
Line monitoring: Blocking diode included. EOL Min. 500 Ohm 2W, or 3k3 Ohm 0.5W resistor or diode (DC versions) can be fitted
Enclosure volume: <2 litres
Installation temp: -55 to +85°C [-67° to +185°F]
Storage temp: -55 to +85°C [-67° to +185°F]
Relative humidity: 99%
95% – Additional tropicalisation is recommended for applications where both high relative humidity and high ambient temperatures exist
Vibration test: 35Hz for a duration 4Hr (UL464)
Jarring test: 3ft/lb Energy (UL464)
Impact test: 3x 5lb (UL464)
Weight: 5.2kg/11.4lbs
Part codes
Part Code:Identifier:Description:
Product type:D1xC2X05Combined Alarm Horn & Xenon Strobe
Horn type:FFlare re-entrant horn
Voltage:DC024
AC115
AC230
20-28V dc
110-120Vac
220-240Vac
Cable entries:[e]A
B
C
D
F
G
Note:
2 x M20x1.5mm & 1 × 1/2"NPT
2 × 1/2"NPT – adaptors
2 × 3/4"NPT – adaptors
2 x M25x1.5mm – adaptors
1 × 3/4"NPT – adaptor
1 x M25x1.5mm – adaptor
All entries, excluding thread adaptors, supplied with stopping plugs installed.
Stopping plug/adaptor material: [m]B
N
S
Brass
Nickel Plated
Stainless Steel
Bracket/Guard material: [s]1
3
5
U bracket A4 316 Stainless Steel
U bracket A4 316 St/St with Equip. Tag
U bracket A4 316 St/St
with Equip. Tag & Duty Label
Product version:[v]AUL, cUL, ULC, IECEx, ATEX, CSFM, INMETRO – SIL1 & SIL2
Product option:[o]1
Z
X
Y
Standard product
Custom alarm tone software – contact E2S
Custom configuration – contact E2S
Stage control Config. 4 or 8
Enclosure colour: [x]G
R
S
Grey
Red
Special colour – contact E2S
Lens colour: [y]A
B
C
G
M
R
Y
Amber
Blue
Clear
Green
Magenta
Red
Yellow
Accessories
SP65-0001-A4
SP65-0003-A4
Please review the installation manual and wiring schematics for remote stage control and EOL resistor monitoring configuration options:
Config. 1 or 5 [DC]:Factory default. Common negative, positive switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only
Config. 2 or 6 [DC]:User setting. Common positive, negative switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only
Config. 3 or 7 [DC]:User setting. Common negative, positive switching activation of Alarm Stages 1 & 2 with EOL on both stages. Reverse polarity monitoring
Config. 4 or 8 [DC]:Product option ‘Y’. Independent activation of Alarm Stages 1 & 2 with EOL on both stages. Forward polarity monitoring
Config. 1 or 2 [AC]:Factory default. Up to 4 Alarm Stages. Stage 1 activated at power on. Stages 2, 3 and 4 via volt free contacts
Current Consumption
Voltagerange:NominalVoltage:Xenon Strobe Nominalcurrent:Alarm Horn Default PowerNominal current:Alarm Horn High PowerNominal current:Combined Default PowerNominal current:Combined High PowerNominal current:Combined Default PowerMaximum current:Combined High PowerMaximum current:In Rush
20-28Vdc24Vdc323mA324mA740mA647mA1063mA647mA1063mA786mA <5ms
110-120Vac
50/60Hz
115Vac130mA125mA285mA255mA415mA291mA478mA
220-240Vac
50/60Hz
230Vac79mA78mA167mA157mA246mA157mA287mA
Approvals
  • UL/cUL/ULC File ref: E230764
  • IECEx Certificate: IECEx ULD 19.0008X
  • ATEX Certificate: DEMKO 19 ATEX 2141X
  • CSFM listing: 7136-2279:0506
  • UKCA certificate: UL21UKEX2132X
  • INMETRO IEx 24.0158X
Coding
  • NEC Class / Zone
    Class I Zone 1 IIC T4 Gb Ta -55°C to +85°C
    Class I Zone 1 IIC T4A Gb Ta -55°C to +80°C
    Class I Zone 1 IIC T5 Gb Ta -55°C to +60°C (T6: +45°C)
  • CEC Class / Zone
    Class I Zone 1 IIC T5 Gb Ta -55°C to +55°C (T6: +45°C)
  • NEC Class / Div
    Class I Div 1 ABCD T4 Ta -55°C to +85°C
    Class I Div 1 ABCD T4A Ta -55°C to +80°C
    Class I Div 1 ABCD T5 Ta -55°C to +60°C (T6: +45°C)
  • CEC Class / Div
    Class I Div 1 ABCD T5 Ta -55°C to +55°C (T6: +45°C)
  • IECEx / ATEX
    II 2G Ex db IIC T4/T5 Gb Ta -55°C to +75°C
    II 2G Ex db IIC T5 Gb Ta -55°C to +55°C
    II 2G Ex db IIC T6 Gb Ta -55°C to +40°C (DC only)
    II 2D Ex tb IIIC T115°C Db Ta ‐55°C to +75°C
    See product manual for full voltage specific coding.
Effective Candela lens colour factor
AmberBlueClearGreenMagentaRedYellow
0.590.271.000.510.340.150.85
Tone Table
Stage 1 WAV file Frequency Description. Stage 2 Stage 3
T1 Any T2
T2 Any T3
T3 Any T2
T4 Any T24
T5 Any T19
T6 Any T44
T7 Any T44
T8 Any T24
T9 Any T34
T10 Any T34
T11 Any T1
T12 Any T1
T13 Any T1
T14 Any T3
T15 Any T24
T16 Any T24
T17 Any T24
T18 Any T24
T19 Any T24
T20 Any T24
T21 Any T24
T22 Any T24
T23 Any T3
T24 Any T20
T25 Any T44
T26 Any T44
T27 Any T44
T28 Any T24
T29 Any T44
T30 Any T24
T31 Any T24
T32 Any T24
T33 Any T24
T34 Any T24
T35 Any T24
T36 Any T24
T37 Any T24
T38 Any T8
T39 Any T8
T40 Any T24
T41 Any T8
T42 Any T8
T43 Any T8
T44 Any T24
T45 Any T8
T46 Any T24
T47 Any T24
T48 Any T24
T49 Any T24
T50 Any T24
T51 Any T24
T52 Any T24
T53 Any T24
T54 Any T24
T55 Any T24
T56 Any T24
T57 Any T24
T58 Any T24
T59 Any T24
T60 Any T24
T61 Any T24
T62 Any T24
T63 Any T24
T64 Any T21

Настройки файлов cookie

Мы используем файлы cookie, чтобы обеспечить вам удобство прохождения собеседований, улучшить наш продукт, персонализировать ваш опыт и поддержать наши маркетинговые усилия. Полный список файлов cookie, используемых по категориям, приведен ниже. Вы можете отказаться/отключиться в любое время. Для получения более подробной информации ознакомьтесь с нашей полной политикой конфиденциальности.

Строго необходимые файлы cookie
Эти файлы cookie необходимы для работы нашего веб-сайта и не могут быть отключены. К ним относятся файлы cookie, используемые для аутентификации и статуса, безопасности, персонализации и функций корзины покупок.
Файлы cookie производительности и аналитики
Эти файлы cookie позволяют нам измерять посещаемость веб-сайта и источники трафика. Мы используем их для определения популярных страниц и оптимизации работы сайта.
Целевые файлы cookie
Эти файлы cookie позволяют нам измерять эффективность нашей маркетинговой программы и устанавливаются нашими рекламными партнерами. Их можно использовать для создания профиля ваших интересов и для показа соответствующей рекламы на других веб-сайтах.

Получить типовой расчет

Предоставьте свои контактные данные, и мы скоро свяжемся с вами!
В этой форме указывается ваше имя и контактная информация. Пожалуйста, ознакомьтесь с нашей политикой конфиденциальности, в которой говорится о том, как мы защищаем и управляем вашими данными.