D2xC2XH2 Horn & Strobe UL464 & UL1971 - Auto Sync Horn 116dB(A) and 70.29cd Xenon

Features and Functions

  • Public mode fire use UL464/UL1971 & CAN/ULC-S525/S526
  • Auto-synchronized for over 2 hours per UL1971
  • 63.73 eff. candela – UL1971 Public mode fire
  • 107dB(A) @ 10ft/3m max. sound output – UL464
  • 64 alarm tones, 4 remotely selectable alarm stages/channels
  • Ultra low combined operating current of 405mA
  • In rush limiting circuit – 2.3A for 9ms
  • Choice of three UL1971 tested flash rates: 1Hz, 1.3Hz, 1.5Hz
  • Marine grade aluminum enclosure
  • Ingress protection Type 4/4X/3R/13, IP66
  • High impact resistant Borosilicate glass lens
  • Duplicate, pluggable cable terminations
  • Supervisory diode
  • Dual 1/2"NPT entries
  • Supplied with haz loc rated stopping plugs/adaptors
Ul badge certified
Ul
Ulc
Iecex approval
Atex approval
Csfm
Ce approval
Ukca

Overview

Multiple D2xC2XH2 units will auto-synchronize when powered from the same power source removing the need for any additional sync modules in the circuit. The horn & strobe can be powered from the same source, simplifying installation and reducing cabling costs. The unit is UL/cUL & ULC approved for Class I Div 2, Class II Div 2, Class I Zone 2/22 as well as IECEx and ATEX certified for Zone 2 and 22 hazardous area applications.
Downloads
Datasheet Download
Installation Manual Download
IECEx certificate Download
ATEX certificate Download
UL certificate of compliance Download
UKCA Certificate Download
CSFM Listing Download
ECAS Ex Approval Download
Declaration of Conformity Download
Declaration of Conformity UKCA Download
2D drawing (PDF) Download
2D drawing (DWG) Download
3D drawing (STEP) Download
Wiring Schematic Download
Nameplate Drawing Download
Equipment Tag Drawing Download
Duty Label Drawing Download
Hi-res product image 1 (TIFF) Download
Hi-res product image 2 (TIFF) Download
Specification
Maximum output: 116dB(A) @ 1 metre [107dB(A) @ 10ft/3m]
Nominal output: 112dB(A) @ 1m +/- 3dB – Tone 2 [103dB(A) @ 10ft/3m]
No. of tones: 64 (UKOOA / PFEER compliant)
No. of stages: 4
Volume control: Adjustable -12dB(A) [Tone 2]
Effective range: 125m/410ft @ 1KHz
Synchronisation: Automatic synchronisation
Flash rates synchronise for a minimum of 2 hours per UL1971
Source: Xenon Strobe
Modes: 1Hz flash (60 fpm)
Eff. Intensity cd: 63.73 cd UL1971 Public mode fire
Peak Candela: 1,000,000 cd – calculated from energy (J)
Effective cd: 500 cd – calculated from energy (J)
Voltage: 24V dc [20-28V dc]
In rush: 2.3A for 9ms
Ingress protection: IP rating per EN60529:IP66
Type rating per UL50E/NEMA250:4/4X/3R/13
Enclosure material: Marine grade LM6 aluminum alloy
Enclosure finish: Chromate & powder coated finish
ISO 12944-6 CX, C5VH & C5H
Enclosure colour: Red
Lens material: Borosilicate glass
Cable entries: 2 × 1/2"NPT
Stopping plugs: Nickel Plated Brass plugs included
Ground/Earth stud: M5
Terminals: 0.5 – 2.5mm² (20-14 AWG)
Line monitoring: Blocking diode included
EOL can be factory fitted
Operating temp: -40 to +50°C [-40° to +122°F]
Storage temp: -40 to +70°C [-40° to +158°F]
Relative humidity: 99% – tropicalised/conformal coated electronics
Weight: 4.00kg/8.82Ibs
Part codes
Part Code:Identifier:Description:
Product type:D2xC2XH2Combination Alarm Horn & Xenon Beacon / Warning Light
Voltage:DC02424V dc (20-28Vdc)
Cable entries: [e]B2 × 1/2” NPT
Stopping plug material: [m]N
S
Nickel plated brass
Stainless Steel
Guard material & tag: [s]0
3
5
No lens Guard
No lens guard with Equip. Tag
No lens guard with Equip. Tag & Duty Label
Product version: [v]HUL, cUL, ULC, IECEx, ATEX, CSFM – UL1971
Product option:[o]1
X
Standard product
Custom configuration – contact E2S
Enclosure colour: [x]RRed
Lens colour: [y]CClear
Accessories
SP65-0001-A4
SP65-0003-A4
Current Consumption
Nominal Voltage:In rush:Voltage range:Nominal operating current:
24V dc2300mA <9.0ms20-28V dc759mA
Approvals
  • UL File ref: E230764
  • IECEx cert: IECEx ULD 14.0004X
  • ATEX cert: DEMKO 14 ATEX 4786493904X
  • CSFM certificate: 7136-2279:0501
Coding
  • NEC / CEC:
    Class I Div 2 ABCD T2A Ta -40°C to +50°C
    Class II Div 2 FG T6 Ta -40°C to +50°C
    Class III Div 1&2 Ta -40°C to +50°C
  • NEC:
    Class I Zone 2 AEx ec IIC T2 Gc Ta -40°C to +50°C
    Zone 22 AEx tc IIIB T85°C Dc Ta -40°C to +50°C
  • CEC:
    Class I Zone 2 Ex ec IIC T2 Gc X Ta -40°C to +50°C
    Zone 22 Ex tc IIIC T85°C Dc Ta -40°C to +50°C
  • IECEx & ATEX:
    II 3G Ex ec IIC T2 Gc Ta -40°C to +50°C
    II 3D Ex tc IIIC T85°C Dc Ta -40°C to +50°C
    See product manual for full voltage specific coding.
Tone Table
Stage 1 WAV file Frequency Description. Stage 2 Stage 3
T 1 T 3 T 2
T 2 T 1 T 3
T 3 T 1 T 2
T 4 T 44 T 24
T 5 T 52 T 19
T 6 T 7 T 44
T 7 T 6 T 44
T 8 T 44 T 24
T 9 T 18 T 34
T 10 T 21 T 34
T 11 T 44 T 1
T 12 T 44 T 1
T 13 T 44 T 1
T 14 T 23 T 3
T 15 T 44 T 24
T 16 T 44 T 24
T 17 T 44 T 24
T 18 T 44 T 24
T 19 T 64 T 24
T 20 T 44 T 24
T 21 T 44 T 24
T 22 T 44 T 24
T 23 T 15 T 3
T 24 T 48 T 20
T 25 T 1 T 44
T 26 T 1 T 44
T 27 T 1 T 44
T 28 T 44 T 24
T 29 T 1 T 44
T 30 T 44 T 24
T 31 T 30 T 24
T 32 T 44 T 24
T 33 T 53 T 24
T 34 T 56 T 24
T 35 T 44 T 24
T 36 T 21 T 24
T 37 T 53 T 24
T 38 T 1 T 8
T 39 T 1 T 8
T 40 T 44 T 24
T 41 T 1 T 8
T 42 T 1 T 8
T 43 T 1 T 8
T 44 T 5 T 24
T 45 T 1 T 8
T 46 T 53 T 24
T 47 T 57 T 24
T 48 T 44 T 24
T 49 T 44 T 24
T 50 T 44 T 24
T 51 T 44 T 24
T 52 T 64 T 24
T 53 T 56 T 24
T 54 T 57 T 24
T 55 T 54 T 24
T 56 T 57 T 24
T 57 T 47 T 24
T 58 T 54 T 24
T 59 T 44 T 24
T 60 T 44 T 24
T 61 T 44 T 24
T 62 T 44 T 24
T 63 T 44 T 24
T 64 T 44 T 21

Настройки файлов cookie

Мы используем файлы cookie, чтобы обеспечить вам удобство прохождения собеседований, улучшить наш продукт, персонализировать ваш опыт и поддержать наши маркетинговые усилия. Полный список файлов cookie, используемых по категориям, приведен ниже. Вы можете отказаться/отключиться в любое время. Для получения более подробной информации ознакомьтесь с нашей полной политикой конфиденциальности.

Строго необходимые файлы cookie
Эти файлы cookie необходимы для работы нашего веб-сайта и не могут быть отключены. К ним относятся файлы cookie, используемые для аутентификации и статуса, безопасности, персонализации и функций корзины покупок.
Файлы cookie производительности и аналитики
Эти файлы cookie позволяют нам измерять посещаемость веб-сайта и источники трафика. Мы используем их для определения популярных страниц и оптимизации работы сайта.
Целевые файлы cookie
Эти файлы cookie позволяют нам измерять эффективность нашей маркетинговой программы и устанавливаются нашими рекламными партнерами. Их можно использовать для создания профиля ваших интересов и для показа соответствующей рекламы на других веб-сайтах.

Получить типовой расчет

Предоставьте свои контактные данные, и мы скоро свяжемся с вами!
В этой форме указывается ваше имя и контактная информация. Пожалуйста, ознакомьтесь с нашей политикой конфиденциальности, в которой говорится о том, как мы защищаем и управляем вашими данными.