STExC1X05F Alarm Horn & Xenon Strobe Beacon Alarm Horn & Xenon

Features and Functions

  • Maximum sound pressure level output of 115dB(A)
  • Choice of 64 alarm tone frequencies
  • 4 remotely selectable alarm stages/channels
  • Positive or negative line stage/channel switching
  • Automatic synchronisation on multi-beacon & sounder systems
  • User selectable strobe flash rates
  • Field replaceable lens colour filter
  • Ratchet adjustable 316 stainless steel bracket
  • Triple cable entries
  • Available with custom tone configurations and frequencies
  • Robust corrosion proof 316L stainless steel enclosure
Inmetro
Ul badge certified
Ul
Iecex approval
Atex approval
Ex eac logo
Eac logo
Peso
Ce approval
Ukca

Overview

Featuring 64 alarm tone sounds, each of the available 4 stage/channels can be remotely triggered. Class D amplification provides a high sound output at optimum operating current. The threaded flameproof joint, multiple cable entries and duplicated, pluggable termination simplifies both installation and routine maintenance. SIL1 & SIL2 Route 2H compliant to IEC61508 (2010) as standard.
Downloads
Datasheet Download
INMETRO Installation Manual Download
IECEx certificate Download
ATEX certificate Download
UL certificate of compliance Download
UKCA Certificate Download
INMETRO certificate Download
Ex EAC TR CU 012/2011 Certificate Download
CCOE PESO Download
ECAS Ex Approval Download
Ingress Protection certificate Download
Declaration of Conformity Download
Declaration of Conformity UKCA Download
2D drawing (PDF) Download
2D drawing (DWG) Download
3D drawing (STEP) Download
Wiring Schematic DC voltage Download
Wiring Schematic AC voltage Download
Nameplate Drawing Download
Equipment Tag Drawing Download
Duty Label Drawing Download
Pole Mount & Sun Shade Drawing Download
Specification
Maximum output: 115dB(A) @ 1 m +/- 3dB [109dB(A) @ 10ft/3m +/- 3dB]
Nominal output: 110dB(A) @ 1m +/- 3dB [106dB(A) @ 10ft/3m] +/- 3dB
No. of tones: 64 (UKOOA / PFEER compliant)
No. of stages: 4
Volume control: Full range
Effective range: 125m/410ft @ 1KHz
Voltages DC: 12Vdc (11.5-14Vdc), 24Vdc (20-28Vdc), 48Vdc (42-54Vdc
Voltages AC: 230vac (220-240vac)
Stage switching: DC units: negative or positive
AC units: common supply line
Energy: 5 Joules (5Ws)
Flash rates: 1Hz flash (60 fpm)
1.5Hz flash (90 fpm)
Double flash (120 fpm)
Eff. Intensity: 143 cd* – measured ref. to I.E.S.
250 cd – calculated from energy (J)
Peak Candela: 46,976 cd* – measured ref. to I.E.S.
500,000 cd – calculated from energy (J)
Lens colours: Amber, Blue, Clear, Green, Magenta, Red & Yellow
Tube life : Emissions are reduced to 70% after 5 million flashes
Safety Integrity Level: SIL1 and SIL2 Route 2H IEC61508 (2010)
Ingress protection: EN60529: IP66
Enclosure material: 316L Stainless Steel
Enclosure colour: Red
Enclosure finish: Chromate & powder coated finish
ISO 12944-6 CX, C5VH & C5H
Cable entries: 3 x M20x1.5mm
Stopping plugs included
Stopping plugs: Stainless Steel
Terminals: 0.5 – 2.5mm² (20-14 AWG)
Pluggable & duplicated terminals
Line monitoring: Diode polarized for use in supervised circuits
Blocking diode for reverse polarity monitoring
Blocking diode included
EOL Min. 500 Ohm 2W, or 3k3 Ohm 0.5W resistor
or diode (DC versions) can be fitted
Ground/Earth stud: M5
Enclosure volume: <2 litres
Installation temp: -50° to +70°C (-58°F to +158°F)
Storage temp: -50° to +70°C (-58°F to +158°F)
Relative humidity: 99%
Weight: 7.45kg/16.42lbs
Part codes
Part Code:Identifier:Description:
Product type:STExC1X05STExC1 Combined Alarm
Horn type:FFlare re-entrant horn
Voltage:DC012
DC024
DC048
AC230
11.5-14Vdc
20-284Vdc
42-54Vdc
220-240Vac
Cable entries:[e]A
B
C
D
E
F
G
3 x M20x1.5mm
2 × 1/2" NPT – adaptors
2 × 3/4" NPT – adaptors
2 x M25x1.5mm – adaptors
1 × 1/2" NPT – adaptor
1 × 3/4" NPT – adaptor
1 x M25x1.5mm – adaptor
Stopping plug/adaptor material: [m]B
N
S
Brass
Nickel Plated
Stainless Steel (standard)
Bracket / Guard material: [s]1
3
A4 316 Stainless Steel
A4 316 St/St with Equip. Tag
Product version: [v]AUL, cUL, IECEx, ATEX, Ex EAC, INMETRO – SIL1 & SIL2
Note: UL, cUL approval not applicable to 12Vdc or 115Vac variants
Product option:[o]1
Z
X
Y
Standard product
Custom alarm tone software – contact E2S
Custom configuration – contact E2S
Stage control Config. 4 or 8
Enclosure colour: [x]R
S
Red
Special colour – contact E2S
Lens colour: [y]A
B
C
G
M
R
Y
Amber
Blue
Clear
Green
Magenta
Red
Yellow
Accessories
SP65-0001-A4
SP65-0003-A4
Please review the installation manual and wiring schematics for remote stage control and EOL resistor monitoring configuration options:
Config. 1 or 5 [DC]:Factory default. Common negative, positive switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only
Config. 2 or 6 [DC]:User setting. Common positive, negative switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only
Config. 3 or 7 [DC]:User setting. Common negative, positive switching activation of Alarm Stages 1 & 2 with EOL on both stages. Reverse polarity monitoring
Config. 4 or 8 [DC]:Product option ‘Y’. Independent activation of Alarm Stages 1 & 2 with EOL on both stages. Forward polarity monitoring
Config. 1 or 2 [AC]:Factory default. Up to 4 Alarm Stages. Stage 1 activated at power on. Stages 2, 3 and 4 via volt free contacts
Current Consumption
NominalVoltage:Voltagerange:Alarm Horn Nominalcurrent:Xenon Strobe Nominalcurrent:Combined Nominalcurrent:Combined Max.current:In Rush
12Vdc11.5-14Vdc221mA678mA885mA920mA
24Vdc20-28Vdc185mA323mA508mA555mA786mA <5ms
48Vdc42-54Vdc115mA198mA325mA420mA
230Vac220-240Vac
50/60Hz
48mA79mA127mA149mA
Approvals
  • UL/cUL – File ref: E230764
  • IECEx ULD 16.0017X
  • ATEX DEMKO 16 ATEX 1466X
  • TR-CU Ex EAC certificate: RU С-GB.НА65.В.01252_21
  • INMETRO IEx 20.0156X
  • PESO CCOE certified: P622994
Coding
  • NEC / Class / Zone (24Vdc & 230Vac only)
    Class I Zone 1 AEx db IIC T4 Ta -50°C to +70°C
    Class I Zone 1 AEx db IIC T5 Ta -50°C to +50°C (AC: 48°C)
  • CEC / Class / Zone (24Vdc & 230Vac only)
    Class I Zone 1 Ex db IIC T4 Ta -50°C to +70°C
    Class I Zone 1 Ex db IIC T5 Ta -50°C to +50°C (AC: 45°C)
  • NEC / CEC Class / Div (24Vdc & 230Vac only)
    Class I Div 2 ABCD T4 Ta -50°C to +70°C
    Class I Div 2 ABCD T5 Ta -50°C to +50°C (AC: 45°C)
  • IECEx / ATEX
    II 2G Ex db IIC Gb T4 Ta -50°C to +70°C
    II 2G Ex db IIC Gb T5 Ta -50°C to +50°C (AC: 45°C)
    II 2D Ex tb IIIC Db T114°C Ta -50°C to +70°C (AC: T117°C)
Effective Candela lens colour factor
AmberBlueClearGreenMagentaRedYellow
0.590.271.000.510.340.150.85
Tone Table
Stage 1 WAV file Frequency Description. Stage 2 Stage 3
T 1 Any T 2
T 2 Any T 3
T 3 Any T 2
T 4 Any T 24
T 5 Any T 19
T 6 Any T 44
T 7 Any T 44
T 8 Any T 24
T 9 Any T 34
T 10 Any T 34
T 11 Any T 1
T 12 Any T 1
T 13 Any T 1
T 14 Any T 3
T 15 Any T 24
T 16 Any T 24
T 17 Any T 24
T 18 Any T 24
T 19 Any T 24
T 20 Any T 24
T 21 Any T 24
T 22 Any T 24
T 23 Any T 3
T 24 Any T 20
T 25 Any T 44
T 26 Any T 44
T 27 Any T 44
T 28 Any T 24
T 29 Any T 44
T 30 Any T 24
T 31 Any T 24
T 32 Any T 24
T 33 Any T 24
T 34 Any T 24
T 35 Any T 24
T 36 Any T 24
T 37 Any T 24
T 38 Any T 8
T 39 Any T 8
T 40 Any T 24
T 41 Any T 8
T 42 Any T 8
T 43 Any T 8
T 44 Any T 24
T 45 Any T 8
T 46 Any T 24
T 47 Any T 24
T 48 Any T 24
T 49 Any T 24
T 50 Any T 24
T 51 Any T 24
T 52 Any T 24
T 53 Any T 24
T 54 Any T 24
T 55 Any T 24
T 56 Any T 24
T 57 Any T 24
T 58 Any T 24
T 59 Any T 24
T 60 Any T 24
T 61 Any T 24
T 62 Any T 24
T 63 Any T 24
T 64 Any T 21

Настройки файлов cookie

Мы используем файлы cookie, чтобы обеспечить вам удобство прохождения собеседований, улучшить наш продукт, персонализировать ваш опыт и поддержать наши маркетинговые усилия. Полный список файлов cookie, используемых по категориям, приведен ниже. Вы можете отказаться/отключиться в любое время. Для получения более подробной информации ознакомьтесь с нашей полной политикой конфиденциальности.

Строго необходимые файлы cookie
Эти файлы cookie необходимы для работы нашего веб-сайта и не могут быть отключены. К ним относятся файлы cookie, используемые для аутентификации и статуса, безопасности, персонализации и функций корзины покупок.
Файлы cookie производительности и аналитики
Эти файлы cookie позволяют нам измерять посещаемость веб-сайта и источники трафика. Мы используем их для определения популярных страниц и оптимизации работы сайта.
Целевые файлы cookie
Эти файлы cookie позволяют нам измерять эффективность нашей маркетинговой программы и устанавливаются нашими рекламными партнерами. Их можно использовать для создания профиля ваших интересов и для показа соответствующей рекламы на других веб-сайтах.

Получить типовой расчет

Предоставьте свои контактные данные, и мы скоро свяжемся с вами!
В этой форме указывается ваше имя и контактная информация. Пожалуйста, ознакомьтесь с нашей политикой конфиденциальности, в которой говорится о том, как мы защищаем и управляем вашими данными.