D2xH1 Heat Detector Heat Detector - Aluminium Zone 2/22 Class I/II Div 2

Features and Functions

  • Robust corrosion proof LM6 marine grade aluminium enclosure
  • Ingress protection IP66/67 Type: 4/4X
  • Compact enclosure
  • Multiple cable entries
  • Stopping plugs supplied
  • UL521 and CAN/ULC-S530 approved
  • EN54-5 compliant
  • D-A-F rate compensated heat detector elements
  • Versatile: various temperature settings available
  • Durable: long lasting stainless steel element shell
  • Reliable: hermetically sealed internal contact area
  • Economical: wide installation spacing reduces installation costs
  • Factory set temperature
  • Globally approved to IECEx, ATEX, UL, cUL and ULC standards
  • Version E: Zone 2, Zone 22, Class I/II Div 2
  • Version I & R: Zone 0, Zone 21, Class I/II Div 1
Ul badge certified
Ul
Ulc
Iecex approval
Atex approval
Ce approval
Ukca
Culs approval

Overview

The robust IP66/67, Type 4/4X corrosion proof junction box enclosure is manufactured from marine grade, copper free LM6 aluminium. The E2S D2xH1 heat detector offers a robust and reliable source for alarm initiation in the most hazardous and demanding of applications.
Downloads
Datasheet Download
Installation Manual Download
Installation Manual Download
Technical Bulletin Download
IECEx certificate Download
IECEx certificate Download
ATEX certificate Download
ATEX certificate Download
UL certificate of compliance Download
UKCA Certificate Download
UKCA Certificate Download
ECAS Ex Approval Download
ECAS Ex Approval Download
Declaration of Conformity Download
Declaration of Conformity Download
SIL2 Certificate Download
Declaration of Conformity UKCA Download
Declaration of Conformity UKCA Download
2D drawing (PDF) Download
2D drawing (DWG) Download
3D drawing (STEP) Download
3D drawing (STEP) Download
Wiring Schematics -E Download
Wiring Schematics -I and -R Download
Nameplate Drawing Download
Nameplate Drawing Download
Equipment Tag Drawing Download
Duty Label Drawing Download
Specification
Enclosure: Marine grade LM6 aluminium
Enclosure colour: Red or Grey
Enclosure finish: Chromate & powder coated finish
ISO 12944-6 CX, C5VH & C5H
Ingress protection: IP66/67 EN50029, Type 4/4X UL50E
Cable entries: 2 × 3/4"NPT with 2 x M20x1.5mm or 2 × 1/2"NPT
Stopping plug(s) included
Cable spec: Solid core: 0.5-2.5mm2 AWG20-12
Stranded core: 0.5-2.5mm2 AWG24-14
Terminals: DIN Rail AKZ 2.5 × 6
Max Input 32Vdc: 1A, 24Vdc: 2A, 32Vac 50/60Hz: 5A – version E
Max Power 1.25W – version E
Safety parameters: Ui=30V, Ii=500mA, Pi=1100mW, Ci=0, Li=0 – version I & R
Stopping plugs: Brass, Nickel Plated or Stainless Steel
Grounding stud: M5
Installation temp: -40° to +50°C (-40°F to +122°F)
Storage temp: -40° to +50°C (-40°F to +122°F)
Weight: 1.5kg/3.31Ibs
Note Temperature and spacing data
Derating Factor for Ceiling Height – based on NFPA guidelines
°FSetting °F
Tolerance
140 +7/-8
160 +7/-8
190 +7/-8
210 +7/-8
225 +7/-8
275 ±10
325 ±10
360 ±10
450 ±15
500 ±15
600 ±20
725 ±20
Ceiling Height Above Up to and Including
m ft
0 0
3.05 10
3.66 12
4.27 14
4.88 16
5.49 18
6.10 20
6.71 22
7.32 24
7.93 26
8.54 28
Part codes
Part Code:Identifier:Description:
Product type:D2xH1Heat Detector
Element orientation: [d]H
V
Horizontal
Vertical
Element guard:[g]N
G
No guard
With guard
Temperature code:[t]01
02
03
04
05
06
07
08
09
10
11
12
140°F / 60°C
160°F / 71°C
190°F / 88°C
210°F / 99°C
225°F / 107°C
275°F / 135°C
325°F / 163°C
360°F / 182°C
450°F / 232°C
500°F / 260°C
600°F / 316°C
725°F / 385°C
Cable entries:[e]A
B
C
Note:
2 x M20 & 2 × 1/2"NPT (Vertical orientation)
2 x M20 (Horizontal orientation)
2 × 1/2"NPT (Horizontal orientation)
All types also contain 2 × 3/4” NPT side & 1 × 3/4” NPT pendant entries
Stopping plug/adaptor material: [m]B
N
S
Brass
Nickel Plated
Stainless Steel
Equipment tag: [s]1
2
3
6
7
No Duty label, no Equip. tag
Duty label
Duty label + Equip. tag
Equip. tag only
Special label requirement
Product version: [v]E
I
R
Note:
Zone 2/22, Class I/II Div 2
Zone 0/21, Class I/II Div 1
Zone 0/21, Class I/II Div 1
with EOL and/or series devices
Versions E, I & R: IECEx, ATEX, UL, cUL, ULC
Product option: [o]1
W
X
Standard product
Alternate EOL & series wiring
Custom configuration – contact E2S
Enclosure colour: [x]R
G
S
Red
Grey
Special – contact E2S for alternative enclosure colours
LED indicator: [u]:N
L
C
Note:
No LED
LED with 1.5K ballast resistor
LED without ballast resistor <20mA
LED only available with Product version ‘R’
For product version E and R only, suffix the part code with required EOL and series devices as follows for factory installation.See the D2xH1-E and D2xH1-IR installation manuals for resistance, wattage and diode specifications:
E.O.L.Module: [e]optionalExxxR
ED1
ExxxZ
Resistor value in Ohms e.g. E470R = 470 Ohm
Diode IN5401 = ED1
Zener diode e.g. E5V1Z = 5.1V
Series Module: [s]optionalSxxxR
SD1
SxxxZ
Resistor value in Ohms e.g. S1K5R = 1.5K Ohm
Diode IN5401 = SD1
Zener diode e.g. S5V1Z = 5.1V
Approvals
  • UL/cUL – File ref: E245313
  • IECEx ULD 14.0004X
  • ATEX DEMKO 14ATEX4786493904X
  • UKCA UL21UKEX2131X
  • SIL2 compliant to IEC61508 (2010)
Coding

D2xH1-E: Product version: E
IECEx / ATEX
Ex db ec IIC T6 Gc Ta –40°C to +50°C
Ex tc IIIC T55°C Dc Ta –40°C to +50°C
NEC Class Zone
Class I Zone 2 AEx db ec IIC T6 Gc Ta -40°C to +50°C
Zone 22 AEx tc IIIC T55°C Dc Ta -40°C to +50°C
CEC Class Zone
Ex db ec IIC T6 Gc Ta –40°C to +50°C
Ex tc IIIC T55° Dc Ta –40°C to +50°C
NEC / CEC Class Division
Class I Div 2 ABCD T6 Ta -40°C to +50°C
Class II Div 2 FG T6 Ta -40°C to +50°C
Class III Div 2 Ta -40°C to +50°C
D2xH1-I: Product version: I
IECEx / ATEX
Ex ia IIC T6 Ga Ta –40°C to +50°C
Ex tb IIIC T75°C Db Ta –40°C to +50°C
NEC Class Zone
Class I Zone 0 AEx ia IIC T6 Ga Ta -40°C to +50°C
Zone 21 AEx tb IIIC T75°C Db Ta -40°C to +50°C
CEC Class Zone
Ex ia IIC T6 Ga X Ta -40°C to +50°C
Ex tb IIIC T75°C Db X Ta -40°C to +50°C
NEC / CEC Class Division
Class I Div 1 Group ABCD T6 Ta -40°C to +50°C
Class II Div 2 Group FG T6 Ta -40°C to +50°C
Class III Div 2 Ta -40°C to +50°C
D2xH1-IR: Product version: R
IECEx / ATEX
Ex ia IIC T4 Ga Ta –40°C to +50°C
Ex tb IIIC T75°C Db Ta –40°C to +50°C
NEC Class Zone
Class I Zone 0 AEx ia IIC T4 Ga Ta -40°C to +50°C
Zone 21 AEx tb IIIC T75°C Db Ta Ta -40°C to +50°C
CEC Class Zone
Ex ia IIC T4 Ga X Ta -40°C to +50°C
Ex tb IIIC T75°C Db X Ta -40°C to +50°C
NEC / CEC Class Division
Class I Div 1 Group ABCD T4 Ta -40°C to +50°C
Class II Div 2 Group FG T4 Ta -40°C to +50°C
Class III Div 2 Ta -40°C to +50°C
See installation manuals for full coding

Note
  • E2S H1 detector temperature is factory set.
  • Per UL521 requirements – low temperature exposure test is – 22°F (-30°C)
  • E2S H1 detectors are designed for long life expectancy, however due to various field conditions it is required that the detectors be tested annually per NFPA guidelines or local fire codes.
  • Replace the detector after any fire or heat related event, any mechanical damage, or after 10 years of continuous service.
  • To avoid nuisance activations, select a temperature setting a minimum of 100°F above the maximum ambient expected temperature.

Настройки файлов cookie

Мы используем файлы cookie, чтобы обеспечить вам удобство прохождения собеседований, улучшить наш продукт, персонализировать ваш опыт и поддержать наши маркетинговые усилия. Полный список файлов cookie, используемых по категориям, приведен ниже. Вы можете отказаться/отключиться в любое время. Для получения более подробной информации ознакомьтесь с нашей полной политикой конфиденциальности.

Строго необходимые файлы cookie
Эти файлы cookie необходимы для работы нашего веб-сайта и не могут быть отключены. К ним относятся файлы cookie, используемые для аутентификации и статуса, безопасности, персонализации и функций корзины покупок.
Файлы cookie производительности и аналитики
Эти файлы cookie позволяют нам измерять посещаемость веб-сайта и источники трафика. Мы используем их для определения популярных страниц и оптимизации работы сайта.
Целевые файлы cookie
Эти файлы cookie позволяют нам измерять эффективность нашей маркетинговой программы и устанавливаются нашими рекламными партнерами. Их можно использовать для создания профиля ваших интересов и для показа соответствующей рекламы на других веб-сайтах.

Получить типовой расчет

Предоставьте свои контактные данные, и мы скоро свяжемся с вами!
В этой форме указывается ваше имя и контактная информация. Пожалуйста, ознакомьтесь с нашей политикой конфиденциальности, в которой говорится о том, как мы защищаем и управляем вашими данными.