GNExCP7-PT/M-I IS Tool Reset/Momentary Call Point Tool Reset Manual Station Call Point

Features and Functions

  • Corrosion proof GRP enclosure, anti-static & UV stable
  • Ingress protection IP66/67/68, 4/4X/3R/13
  • Single or double switch (SPCO/DPCO)
  • 316 (A4) stainless steel mechanism
  • 3 x cable entries, 2 x stopping plugs included
  • Optional LED indicator
Ul badge certified
Ul
Iecex approval
Atex approval
Dnv
Csfm
Ce approval
Ukca
Culs approval

Overview

Globally approved to IECEx, ATEX, UL and cUL standards for all Class I Div 1 and Zone 0 installations. Available with DIN rail terminals or the innovative E2S termination board with dedicated connections for EOL and/or series devices. SIL2 compliant to IEC 61508 (2010). DNV type approved for exposed locations.
Downloads
Datasheet Download
Installation Manual Download
IECEx certificate Download
ATEX certificate Download
UL certificate of compliance Download
UKCA Certificate Download
DNV Type Approval Download
ECAS Ex Approval Download
Ingress Protection certificate Download
Declaration of Conformity Download
SIL2 Certificate Download
Declaration of Conformity UKCA Download
2D drawing (PDF) Download
2D drawing (DWG) Download
3D drawing (STEP) Download
Wiring Schematics - DIN Rail Terminals Download
Wiring Schematics - PCB Terminals Download
Nameplate Drawing Download
Equipment Tag Drawing Download
Duty Label Drawing Download
Pole Mount & Sun Shade Drawing Download
Specification
GNExCP7-PT-IGNExCP7-PM-I Version: IS Tool Reset
Version: IS Momentary
Temp. Range: -55°C to +60°C/+70°C
Switch: Sealed – IP67
Ingress protection: IP66/67/68 to EN/IEC 60529
4/4X/3R/13 to UL50E/NEMA250
Enclosure matl: GRP Glass Reinforced Polyester, anti-static & UV stable
Colour: Red
Other solid and striped colours available
Lift flap: Latching lift flap included as standard
Cable entries: 2 x M20x1.5 down facing and 1 x M20x1.5 side
Can be rotated to provide 2 x top facing and 1 x side entries
Cable entries adaptable to 1/2"NPT, 3/4"NPT & M25
Stopping plugs: 2 x Stopping plugs as standard
Brass, Nickel plated or Stainless Steel
Terminals: DIN rail 8 × 2.5mm² SAK2.5 or
Termination board featuring 6 × 2.5mm² terminals plus 4 x dedicated EOL & Series terminals
Earth: External M5 earth connection
Relative Humidity: R.H. 95% @ 20°C
MTBF: 479.6 years / 4,201,680 hours ​- MIL 217
Weight: 2.1Kg/4.63Ibs
Supply voltage: 24Vdc Nominal 30Vdc Maximum via barriers
Input safetyparameters: Ui
Ii
Pi
Ci
Li
Component: Value:
End-of-Line Resistor min. 470R / 2W or
min. 2k2 / 0.5W
5% Max. tolerance.
Min. size: Ø3.5 × 9.0mm 2W or Ø2.6 × 6.8mm 0.5W
Type 1N5401. Min. size: Ø4.8 × 7.2mm
5% Max. tolerance.
Min. size: Ø3.5 × 9.0mm 2W or Ø2.6 × 6.8mm 0.5W
Type 1N5401. Min. size: Ø4.8 × 7.2mm
End-of-Line Diode 2W
Series Resistor min. 470R / 2W or
min. 2k2 / 0.5W
Series Diode 2W
Series Zener DiodeType 1N53xxBØ3.3 × 8.4mmMin component size 3V3
4V7
5V1
5V6
6V2
6V8
10V
12V
Note Spares:
Accessories:
SP70-0001SP70-0040 Replacement break glass elements (Pack of 50)
STxCP8-BG Test Key
SP65-0001-A4SP65-0002-A4SP70-0065 Pole Mount Bracket Kit St/St A4 (316)
Sunshade – St/St A4 (316)
Break glass hammer with chain
Part codes
Part Code:Identifier:Description:
Product type:GNExCP7PT
GNExCP7PM
IS Latching push button with tool reset
IS Momentary push button
Switch type: [s]S
D
SPCO/SPDT
DPCO/DPDT
Terminals: [t]D
P
DIN Rail 8 × SAK2.5
PCBA termination: 6 × 2.5mm² plus 4 × EOL & Series terminals
NOTE:
D option only available if no EOL, series or LED are required
P option only available if EOL, series or LED are required to be factor fitted or installed during installation
Lift flap: [l]LLift flap supplied as standard
Cable entries:[e]A
B
C
D
E
F
G
3 x M20x1.5mm
2 × 1/2" NPT – adaptors
2 × 3/4" NPT – adaptors
2 x M25x1.5mm – adaptors
1 × 1/2" NPT – adaptor
1 × 3/4" NPT – adaptor
1 x M25x1.5mm – adaptor
Stopping plug/ adaptor material: [m]B
P
S
Brass
Nickel Plated Brass
Stainless Steel
Duty label/Equipment tag: [d]:1
2
3
4
5
6
7
No Duty label, no Equip. tag
Duty label Stainless Steel
Duty label St/St + Equip. tag
Duty label Metalised Polyester
Duty label M. Poly. + Equip. tag
Equip. tag only
Special label requirement
Product version: [v]IUL, cUL, IECEx, ATEX, DNV
Product option: [o]1
R
W
Standard product
With EOL, series and/or LED devices
Alternate EOL wiring
Enclosure colour: [x]R
B
N
Y
V
S
K
M
Z
Red
Blue
Green
Yellow
Red/White
Yellow/Black
Black
Magenta
Red/Black
LED indicator: [u]N
L
C
No LED required
LED with 1.5K ballast resistor
LED without ballast resistor
E.O.L.Module: [e]optionalExxxR
ED1
ExxxZ
Resistor value in Ohms e.g. E470R = 470 Ohm
Diode IN4007 = ED1
Zener diode e.g. E5V1Z = 5.1V
Series Module: [s]optionalSxxxR
SD1
SxxxZ
Resistor value in Ohms e.g. S1K5R = 1.5K Ohm
Diode IN4007 = SD1
Zener diode e.g. S5V1Z = 5.1V
Approvals
  • UL/cUL cert: UL-US-L513632-352311-42200202-2
  • IECEx cert: IECEx ULD 19.0007X
  • ATEX cert: DEMKO 19 ATEX 2101X
  • UKCA cert: UL21UKEX2134X
  • DNV cert: TAA000034V
  • SIL 2 compliant to IEC 61508 (2010)
Coding
  • NEC Class / Zone
    Class I Zone 0 AEx ia IIC T6 Ga Ta -55°C to +70°C
  • CEC Class / Zone
    Ex ia IIC T6 Ga Ta –55°C to +70°C
  • NEC / CEC Class / Div
    Class I Div 1 Group ABCD T6 Ta -55°C to +70°C
  • IECEx / ATEX
    II 1G Ex ia IIC T6 Ga Ta –55°C to +70°C
    Note: All rated to T4 with EOL, series and/or LED.

Настройки файлов cookie

Мы используем файлы cookie, чтобы обеспечить вам удобство прохождения собеседований, улучшить наш продукт, персонализировать ваш опыт и поддержать наши маркетинговые усилия. Полный список файлов cookie, используемых по категориям, приведен ниже. Вы можете отказаться/отключиться в любое время. Для получения более подробной информации ознакомьтесь с нашей полной политикой конфиденциальности.

Строго необходимые файлы cookie
Эти файлы cookie необходимы для работы нашего веб-сайта и не могут быть отключены. К ним относятся файлы cookie, используемые для аутентификации и статуса, безопасности, персонализации и функций корзины покупок.
Файлы cookie производительности и аналитики
Эти файлы cookie позволяют нам измерять посещаемость веб-сайта и источники трафика. Мы используем их для определения популярных страниц и оптимизации работы сайта.
Целевые файлы cookie
Эти файлы cookie позволяют нам измерять эффективность нашей маркетинговой программы и устанавливаются нашими рекламными партнерами. Их можно использовать для создания профиля ваших интересов и для показа соответствующей рекламы на других веб-сайтах.

Получить типовой расчет

Предоставьте свои контактные данные, и мы скоро свяжемся с вами!
В этой форме указывается ваше имя и контактная информация. Пожалуйста, ознакомьтесь с нашей политикой конфиденциальности, в которой говорится о том, как мы защищаем и управляем вашими данными.