D2xB1XH1 Haz Loc UL1971 Xenon Strobe 18.18cd Xenon Beacon

Features and Functions

  • UL1971/UL1638 Public mode fire
  • CAN/ULC-S526 Fire approved
  • 18.18 eff. candela
  • Synchronised for over 2 hours per UL1971
  • Xenon tube mechanically secured against vibration & shock
  • Marine grade aluminum enclosure
  • Ingress protection Type 4/4X/3R/13, IP66
  • High impact resistant Borosilicate glass lens
  • Stainless steel external and internal fixings
  • Duplicate, pluggable cable terminations, supervisory diode
  • Conduit mounting via integral 3/4" NPT entry
  • Surface mounting via user installed lugs
  • Pendant mounting via 3/4"NPT conduit entry
  • Dual 1/2"NPT and M20 cable entries
  • Supplied with haz loc rated stopping plugs/adaptors
  • UL Marine approved
Ul badge certified
Ul
Ulc
Iecex approval
Atex approval
Csfm
Ce approval
Ukca

Overview

Multiple D2xB1XH1 units will auto-synchronize when powered from the same power source removing the need for any additional sync modules in the circuit. One device, worldwide certification: NEC/CEC CI D2 and CII D2; NEC CI Zone 2 and Zone 22; CEC Zone 2 & 22 and CII D2; ATEX, IECEx Zone 2 & 22. UL1638/UL1971 & CAN-ULC-S526 tested – suitable for public mode fire alarm, ADA compliant, hearing impaired applications.
Downloads
Datasheet Download
Installation Manual Download
IECEx certificate Download
ATEX certificate Download
UL certificate of compliance Download
CSFM Listing Download
UKCA Certificate Download
ECAS Ex Approval Download
Declaration of Conformity Download
Declaration of Conformity UKCA Download
2D drawing (PDF) Download
2D drawing (DWG) Download
3D drawing (STEP) Download
Wiring Schematic Download
Nameplate Drawing Download
Equipment Tag Drawing Download
Duty Label Drawing Download
Pole Mount & Sun Shade Drawing Download
Hi-res product image 1 (TIFF) Download
Specification
Energy: 5 Joules (5Ws)
Source: Xenon strobe
Modes: 1Hz flash (60 fpm)
Effective cd: 18.18 cd – UL1971
250 cd – calculated from energy (J)
Peak Candela: 500,000 cd – calculated from energy (J)
Synchronisation: Flash rates synchronise for a minimum of 2 hours per UL1971
Voltages: 24Vdc – 20-28Vdc
Ingress protection: IP rating per EN60529:IP66
Type rating per UL50E/NEMA250:4/4X/3R/13
Enclosure material: Marine grade LM6 aluminum alloy
Enclosure finish: Chromate & powder coated finish
ISO 12944-6 CX, C5VH & C5H
Enclosure colour: Red
Lens colour: Clear
Lens material: Borosilicate glass dome
Cable entries: 2 x M20x1.5, 2 × 1/2"NPT, 1 × 3/4"NPT
Stopping plugs: Nickel Plated Brass plugs included – brass or stainless steel optional
Mounting: Conduit mount via 3/4" NPT entry
Surface mount via supplied lug pack (user installed)
Ground/Earth stud: M5
Terminals: 0.5 – 2.5mm² (20-14 AWG)
Line monitoring: Blocking diode included
EOL can be factory fitted
Operating temp: -40 to +50°C [-40° to +122°F]
Storage temp: -40 to +70°C [-40° to +158°F]
Relative humidity: 99% – tropicalised/conformal coated electronics
Weight: 1.5kg/3.31Ibs
Part codes
Part Code:Identifier:Description:
Product type:D2xB1XH118.18cd 5 Joule Xenon Strobe warning light / beacon
Voltage:DC02424V dc (20-28Vdc)
Cable entries: [e]M2 × 1/2” NPT
2 x M20x1.5
1 × 3/4” NPT
Stopping plug material: [m]N
S
Nickel plated brass
Stainless Steel
Guard material & tag: [s]0
3
5
No lens Guard
No lens guard with Equip. Tag
No lens guard with Equip. Tag & Duty Label
Product version: [v]HUL, cUL, ULC, IECEx, ATEX, CSFM
Product option:[o]1
X
Standard product
Custom configuration – contact E2S
Enclosure colour: [x]RRed
Lens colour: [y]CClear
Accessories
SP65-0001-A4
SP65-0003-A4
Current Consumption
Nominal Voltage:In rush:Voltage range:Flash Rate setting:Nominal operating current:
24V dc800mA <5.4ms20-28V dc1Hz flash (60 fpm)296mA
Approvals
  • UL/cUL File ref: E245313
  • IECEx certficate: IECEx ULD 14.0004X
  • ATEX certificate: DEMKO 14 ATEX 4786493904X
  • CSFM certificate: 7300-2279:0500
Coding
  • NEC / CEC:
    Class I Div 2 ABCD T2D Ta -40°C to +50°C (T3: +45°C)
    Class II Div 2 FG T6 Ta -40°C to +50°C
    Class III Div 1 & 2 Ta -40°C to +50°C
  • NEC:
    Class I Zone 2 AEx ec IIC T2 Gc Ta -40°C to +50°C
    Zone 22 AEx tc IIIB T80°C Dc Ta -40°C to +50°C
  • CEC:
    Class I Zone 2 Ex ec IIC T2 Gc X Ta -40°C to +50°C
    Zone 22 Ex tc IIIC T80°C Dc Ta -40°C to +50°C
  • IECEx & ATEX:
    II 3G Ex ec IIC T2 Gc Ta -40°C to +50°C
    II 3D Ex tc IIIC T80°C Dc Ta -40°C to +50°C
    See product manual for full voltage specific coding.

Настройки файлов cookie

Мы используем файлы cookie, чтобы обеспечить вам удобство прохождения собеседований, улучшить наш продукт, персонализировать ваш опыт и поддержать наши маркетинговые усилия. Полный список файлов cookie, используемых по категориям, приведен ниже. Вы можете отказаться/отключиться в любое время. Для получения более подробной информации ознакомьтесь с нашей полной политикой конфиденциальности.

Строго необходимые файлы cookie
Эти файлы cookie необходимы для работы нашего веб-сайта и не могут быть отключены. К ним относятся файлы cookie, используемые для аутентификации и статуса, безопасности, персонализации и функций корзины покупок.
Файлы cookie производительности и аналитики
Эти файлы cookie позволяют нам измерять посещаемость веб-сайта и источники трафика. Мы используем их для определения популярных страниц и оптимизации работы сайта.
Целевые файлы cookie
Эти файлы cookie позволяют нам измерять эффективность нашей маркетинговой программы и устанавливаются нашими рекламными партнерами. Их можно использовать для создания профиля ваших интересов и для показа соответствующей рекламы на других веб-сайтах.

Получить типовой расчет

Предоставьте свои контактные данные, и мы скоро свяжемся с вами!
В этой форме указывается ваше имя и контактная информация. Пожалуйста, ознакомьтесь с нашей политикой конфиденциальности, в которой говорится о том, как мы защищаем и управляем вашими данными.