| Datasheet | Download |
| INMETRO Installation Manual | Download |
| IECEx certificate | Download |
| ATEX certificate | Download |
| UKCA Certificate | Download |
| INMETRO certificate | Download |
| Ex EAC TR CU 012/2011 Certificate | Download |
| CCOE PESO | Download |
| ECAS Ex Approval | Download |
| Ingress Protection certificate | Download |
| Declaration of Conformity | Download |
| Declaration of Conformity UKCA | Download |
| 2D drawing (PDF) | Download |
| 2D drawing (DWG) | Download |
| 3D drawing (IGS) | Download |
| 3D drawing (STEP) | Download |
| Wiring Schematic | Download |
| Equipment Tag Drawing | Download |
| Duty Label Drawing | Download |
| Pole Mount & Sun Shade Drawing | Download |
| Energy: | 5 Joules (5Ws) |
| Flash rate: | DC voltages: 1Hz (60fpm), 1.5Hz (90fpm) & double flash AC voltages: 1Hz (60fpm) |
| Alarm Stages: | DC units – 2 Double strike pattern can be remotely switched |
| Peak Candela: | 500,000 cd – calculated from energy (J) 45,449 cd – measured ref to I.E.S |
| Eff. Intensity cd: | 250 cd – calculated from energy (J) 117.93 cd – measured ref to I.E.S |
| Lens colours: | Amber, Blue, Clear, Green, Magenta, Red & Yellow |
| Voltages DC: | 12Vdc; 24vdc; 48Vdc |
| Voltages AC: | 115Vac; 230Vac |
| Safety Integrity Level: | SIL1 and SIL2 Route 2H IEC61508 (2010) |
| Ingress protection: | IP66/67 |
| Enclosure matl: | UV stable GRP (glass reinforced polyester) |
| Colour: | Natural Red – can be provided in alternative colours |
| Cable entries: | 2 x M20 ISO (1 stopping plug inc.) Adaptors to M25, 1/2" & 3/4" NPT can be specified |
| Terminals: | 0.5 – 2.5mm² (20-14 AWG) |
| Enclosure volume: | <2 litres |
| MTBF DC: | 192.67 years / 1,687,763 hours – MIL 217 |
| MTBF AC: | 232.02 years / 2,032,520 hours – MIL 217 |
| Line monitoring: | Blocking diode included EOL Min. 500 Ohm 2w, or 3k3 Ohm 0.5w resistor or diode (DC versions) can be fitted |
| Tube life: | Emissions reduced to 70% after 5 million flashes |
| Temperature range: | -50° to +70°C (-58°F to +158°F) |
| Relative humidity: | 99% – tropicalised/conformal coated electronics |
| Weight: | 1.5kg/3.3lbs |
| Note | *All candela data is representative of performance with clear lens at optimum voltage. |
| Part Code: | Identifier: | Description: |
|---|---|---|
| Product type: | GNExB1 | |
| Type: | X05 | Xenon Strobe Beacon 5 Joule |
| Voltage: | DC012 DC024 DC048 AC115 AC230 | 10-14Vdc 20-28Vdc 42-54Vdc 110-125Vac 220-240Vac |
| Cable entries:[e] | A B C D E F G | 2 x M20x1.5mm 2 × 1/2" NPT – adaptors 2 × 3/4" NPT – adaptors 2 x M25x1.5mm – adaptors 1 × 1/2" NPT – adaptor 1 × 3/4" NPT – adapator 1 x M25x1.5mm – adaptor |
| Stopping plugadaptor material: [m] | B N S | Brass Nickel Plated Stainless Steel |
| Guard material:[s] | 1 3 5 | A4 316 Stainless Steel A4 316 St/St with Equip. Tag A4 316 St/St with Equip. Tag and Duty Label |
| Product version: [v] | A | IECEx, ATEX, Ex EAC, PESO, INMETRO – SIL1 & SIL2 |
| Product option: [o] | 1 X | Standard product Custom configuration – contact E2S |
| Enclosure colour: [x] | R S | Red Special colour – contact E2S |
| Lens colour: [y] | A B C G M R Y | Amber Blue Clear Green Magenta Red Yellow |
| Accessories: | SP65-0001-A4 SP65-0002-A4 | Pole Mount Bracket Kit St/St A4 (316) Sunshade – St/St A4 (316) |
| Version: | In Rush: | Voltage: | Current: |
|---|---|---|---|
| 12V dc | 10-14V dc | 437mA | |
| 24V dc | 1.09A 5ms | 20-28V dc | 254mA |
| 48V dc | 42-54V dc | 158mA | |
| 115V ac | 110-125V ac 50/60Hz | 95mA | |
| 230V ac | 220-240V ac 50/60Hz | 54mA |
| Amber | Blue | Clear | Green | Red | Yellow |